Thermal Analysis Testing Solutions

LS-DR-5 Transient Plane Source Thermal Conductivity Analyzer

Configured for ISO 22007-2, ASTM D7984 workflows

LS-DR-5 Transient Plane Source Thermal Conductivity Analyzer is a transient plane source thermal analysis instrument for rapid thermal conductivity and thermal diffusivity measurement for ISO 22007-2, ASTM D7984 workflows.

Range
0.005-300 W/(m·K)
Transient plane source
Accuracy
±3%
Repeatability ≤3%
Test Time
5-160 s
Fast thermal screening

Fast Transient Plane Source Testing

Measures thermal conductivity in 5-160 seconds, helping laboratories accelerate material screening compared with longer steady-state heat-transfer methods.

Broad Conductivity Range

The 0.005-300 W/(m·K) test range supports low-conductivity insulation materials as well as higher-conductivity engineered materials and composites.

Flexible Probe Selection

7.5 mm and 15 mm probe options allow the laboratory to adapt to smaller or larger samples while maintaining appropriate sensor contact and data quality.

Minimal Sample Preparation

Block solids only require a sufficiently smooth surface and adequate dimensions relative to the probe diameter, reducing preparation time for comparative material studies.

Low Thermal Disturbance

Sample temperature rise remains below 15°C during measurement, helping reduce thermal damage and making the workflow suitable for temperature-sensitive materials.

High-Resolution Data Acquisition

Dedicated data acquisition electronics and ARM-based processing support stable signal capture, rapid calculation, and repeatable thermal conductivity output.

Application & Search Guide

Testing Method

Transient Plane Source Thermal Conductivity for thermal analysis laboratories

LS-DR-5 Transient Plane Source Thermal Conductivity Analyzer is configured for transient plane source thermal conductivity in thermal analysis laboratories under ISO 22007-2, ASTM D7984. It supports material producers, civil engineering labs, universities, and inspection agencies that need repeatable test data, clear reporting, and standards-ready workflows.

Technical FAQ

What is LS-DR-5 Transient Plane Source Thermal Conductivity Analyzer used for?

LS-DR-5 Transient Plane Source Thermal Conductivity Analyzer is used for transient plane source thermal conductivity workflows in civil engineering materials laboratories, quality control labs, research programs, and construction material acceptance testing.

Which standards does LS-DR-5 support?

LS-DR-5 supports ISO 22007-2, ASTM D7984. Lithostek can also configure reporting fields, accessories, and calibration documents around local project or laboratory requirements.

Can Lithostek configure LS-DR-5 for my laboratory?

Yes. Lithostek application engineers can review specimen format, target standards, throughput, power supply, data output, and training requirements before quoting a suitable configuration.