Home>Products>THERMAL ANALYSIS>Calorimetry>Differential Thermal Analysis (DTA)
Thermal Analysis Testing Solutions

LS-DTA-1 Series Differential Thermal Analyzer

Configured for ASTM E537, ISO 11358 workflows

LS-DTA-1 Series Differential Thermal Analyzer is a thermal analysis instrument for differential thermal analysis (DTA) and thermal event screening for ASTM E537, ISO 11358 workflows.

Temperature
RT to 1150°C
1450°C variant
Range
0-±2000 μV
Differential signal
Accuracy
0.01 μV
DTA measurement

Differential Temperature Event Detection

Measures temperature difference between sample and reference to identify endothermic and exothermic events such as phase transitions, reactions, decomposition, dehydration, and crystallization.

High-Temperature DTA Options

RT to 1150°C and 1450°C configurations allow laboratories to screen a wide range of inorganic, ceramic, mineral, polymer, and research materials.

Stable Ceramic Furnace Structure

A ceramic furnace design and indirect heating architecture improve temperature uniformity and help reduce pulse radiation effects during DTA measurements.

Sensitive Microvolt Measurement

The 0-±2000 μV measuring range and 0.01 μV DTA accuracy support practical event detection when users need differential response rather than full calorimetric heat-flow data.

Programmable Thermal Methods

Heating, isothermal, and cooling programs help technicians build repeatable DTA methods for material comparison, reaction screening, and teaching demonstrations.

Controlled Atmosphere Screening

Two-channel atmosphere control and adjustable gas flow support inert or oxidative DTA workflows, improving repeatability for reaction and stability studies.

Application & Search Guide

Testing Method

Differential Thermal Analysis (DTA) for thermal analysis laboratories

LS-DTA-1 Series Differential Thermal Analyzer is configured for differential thermal analysis (dta) in thermal analysis laboratories under ASTM E537, ISO 11358. It supports material producers, civil engineering labs, universities, and inspection agencies that need repeatable test data, clear reporting, and standards-ready workflows.

Technical FAQ

What is LS-DTA-1 Series Differential Thermal Analyzer used for?

LS-DTA-1 Series Differential Thermal Analyzer is used for differential thermal analysis (dta) workflows in civil engineering materials laboratories, quality control labs, research programs, and construction material acceptance testing.

Which standards does LS-DTA-1 Series support?

LS-DTA-1 Series supports ASTM E537, ISO 11358. Lithostek can also configure reporting fields, accessories, and calibration documents around local project or laboratory requirements.

Can Lithostek configure LS-DTA-1 Series for my laboratory?

Yes. Lithostek application engineers can review specimen format, target standards, throughput, power supply, data output, and training requirements before quoting a suitable configuration.

ISO 9001 QUALITY
CE COMPLIANCE
GLOBAL LOGISTICS
TECHNICAL SUPPORT
RETURN TO TOP ↑